Poolline steam generators are preferred by the users as they can produce steam in a very short time in places where there is a steam need. The steam ventilator must be as close as possible to the steam exit. Optimum performance can only be maintained by short steam and condensation hoses. Hoses must be laid by a 5-10% leaning in order to prevent sag and crimping.
During functioning, the heat of the back panel of the steam generator increases. (up to max. 60 degrees) for this reason, the structure that the unit is installed must not be made from sensitive material.
The place temperature must be between +5/+40 degrees and the relative humidity must not exceed 80% RH.
The mimimum intervals stated below must be observed. These are essential for providing the necessary ventilation.
Poolline ventilators are not convenient for direct outdoor use.
Steam ventilator must be close to the steam exit.
Optimum performance can only be obtained by the short steam and condensation hoses.
Hoses must be laid by a 5-10% leaning in order to prevent sag and crimping.
During functioning, the heat of the back panel of the steam generator increases. (up to max. 60 degrees)
Please take into account that the structure that the unit is installed is not made from sensitive material.
Place the unit to an area where maintenance can easily be made.